Technical Specifications for Water Cooled Cables
Heat Shield
- Our water cooled cables feature heavy woven heat resistant material that protects the covering from radiated furnace heat.
- The heat shield may be in the form of a loose fitting sleeve or bonded to the outer hose.
- Watteredge offers a wide range of materials for your application
Anti-chafing Gear
- Double groove bumpers are a standard feature of every Watteredge electric arc furnace water cooled cable unless the customer specification requires different abrasion protection or does not require abrasion protection.
- The bumpers are made from tough abrasion resistant rubber for longer life and are spaced evenly on twelve inches for maximum flexibility and longer wear.
- Alternate types of anti-chafing gear can also be furnished, such as continuous sleeve, spiral wrap, loose rings or a combination of spiral wrap and bumpers.
Conductor
- This unique Watteredge conductor design and water cooled cable construction gives the maximum current carrying capacity and the lowest AC/DC ratio due to its similarity to hollow tubular conductors.
- Stranding size is the result of Watteredge experience and designed to insure long cable life.
Core
- The resilient long life core is flexible, yet strong, and retains its shape.
- The combined cable and core design insures complete self-flushing water flow and the most efficient distribution of cooling water possible.
- Since the Watteredge core is a rubber and nylon material there is no friction wear between it and the cable stranding.
Covering
- The water cooled cable covering is made exclusively for Watteredge to our exact specifications to insure long life, maximum flexibility, ozone resistance, heat resistance and abrasion resistance.
- Watteredge coverings provide the most complete di-electric and physical strength and are designed to withstand continuous water pressure, to 90 PSI.
Bands and Water Testing
- High tensile strength stainless steel bands are used on each end of our water cooled cables to assure maximum sealing.
- Every Watteredge water cooled cable receives both a 125 PSI static test and a dynamic water test to duplicate actual operating conditions.
Terminals
- Terminals are machined from high conductivity electronic lead free copper to exacting standards to size and finish.
- Silver plating is done by the tank immersion method using electro-deposited pure fine silver anode bars, or by the electroplating process as determined by our customers’ water cooled cable requirements.